LogicMachine5 KNX CANx LM5p2-KC controller with CAN FT and RS-485 terminals, front view

LogicMachine5 KNX CANx Controller (LM5p2-KC)

AED 6,710.00 Incl. 5% VAT: AED 319.52
Skip to product information
LogicMachine5 KNX CANx LM5p2-KC controller with CAN FT and RS-485 terminals, front view

LogicMachine

LogicMachine5 KNX CANx Controller (LM5p2-KC)

SKU
LM5p2-KC
  • KNX Secure

AED 6,710.00

Incl. 5% VAT: AED 319.52

Need a quote for a project or a larger quantity? Request a project quote

  • Collect: From our Dubai office
  • Delivery: By courier on request, at the carrier's rate. Other GCC countries: your own courier collects from our office.
  • Availability and lead time are confirmed after you order
  • Returns: Refund policy

Documents

Documents are published by the manufacturer. Check the revision for your project.

Specifications

Specifications: LogicMachine5 KNX CANx Controller (LM5p2-KC)
Manufacturer LogicMachine
Category Servers & logic controllers
SKU LM5p2-KC
KNX Secure Yes
Shipping weight 137 g

Source: manufacturer product data.

Overview

The controller to start with when the project will grow through CANx modules. The LogicMachine5 KNX CANx (LM5p2-KC) adds a CAN FT port to KNX/TP and has no DALI or on-board I/O of its own: expansion goes through the CANx range.

  • CAN FT port for CANx. CANx devices sit on the CAN FT bus of a LogicMachine that has a CAN FT port. The LM5Lp2, LM5p2-DW1 and LM5p2-PMC have no CAN FT port.
  • Three serial ports, Modbus and BACnet. Two RS-485 ports and one RS-485 / RS-232 port that switches in software. BACnet/IP server and Modbus RTU/TCP master are built in; Modbus slave and BACnet client use the vendor's script libraries. Binary and numeric KNX objects with Export enabled can be read by a BACnet/IP client. The vendor lists native support for KNX, Modbus, BACnet and MQTT.
  • Applications and scripts. The vendor's application store offers pre-built applications, and Lua scripts cover site-specific logic.
  • Remote programming. Built-in WireGuard, OpenVPN and ZeroTier clients; the datasheet lists KNX device programming from a distance over VPN or ZeroTier.

Where it fits in UAE projects

  • Hotel and apartment-tower projects where room control stays on KNX and the specification asks for a BACnet/IP link to the BMS.
  • Plant rooms where RS-485 Modbus devices and an RS-232 device sit next to a KNX line.
  • Phased fit-outs: install the controller with the first KNX floor and add CANx extension modules on the CAN FT bus as later phases arrive.

Same CAN FT bus, different jobs: the LM5p2-KCD adds a DALI line and the Reactor IO V3 LM5p2-RIO3 adds 16 analog-input-or-digital-output channels. The whole range is under LogicMachine.

Specifications

SpecificationValue
General
Article number LM5p2-KC
Product range LogicMachine5 KNX CANx
Manufacturer Embedded Systems SIA, Riga, Latvia
Physical interfaces
KNX/TP 1
CAN FT 1
RJ45 1 (10/100M Ethernet, passive PoE support)
RS-485 2
RS-485 / RS-232 1 (switchable in software)
USB 2.0 1
Power
Power supply 24 V DC via terminals or passive PoE
Power consumption 1.1 W (minimum, no external load)
Connections
KNX bus / CAN FT bus Bus connection terminal, 0.8 mm²
Power supply and I/O ports Screw terminals, 0.8 mm² .. 1.5 mm²
Indicators
LED 1 Green – System load
LED 2 Green – Normal operation / Red – Reset
Enclosure
Mounting support DIN rail
DIN module width 4
Dimensions WxHxD 72 x 112 x 61 mm
IP degree of protection IP20
Net weight 137 g
Standards compliance
EMC EN61000-6-1; EN61000-6-3
Environment
Operational temperature 0 °C .. +45 °C
Storage temperature -15 °C .. +55 °C
Relative humidity 0% ... 93% (without condensation)
Warranty 2 years

Installation notes

  • CANx devices need a LogicMachine with a CAN FT port for commissioning and for connecting to other protocols, according to the vendor's CANx page.

Documents and safety

Embedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.

Embedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.

You may also like