- KNX Secure
AED 7,470.00
Incl. 5% VAT: AED 355.71
Need a quote for a project or a larger quantity?
- Collect: From our Dubai office
- Delivery: By courier on request, at the carrier's rate. Other GCC countries: your own courier collects from our office.
-
Availability and lead time are confirmed after you order - Returns: Refund policy
Documents
- LM5p2-RIO3 datasheet
- LogicMachine comparison table
- Safety information, installation and general cybersecurity guidelines
Documents are published by the manufacturer. Check the revision for your project.
Specifications
| Manufacturer | LogicMachine |
|---|---|
| Category | Servers & logic controllers |
| SKU | LM5p2-RIO3 |
| KNX Secure | Yes |
| Shipping weight | 187 g |
Source: manufacturer product data.
Overview
Each of the 16 channels works either as an analog input or as a digital output. The LogicMachine5 Reactor IO V3 (LM5p2-RIO3) adds two analog outputs, KNX/TP and a CAN FT port, and the I/O sits in a 6 DIN housing next to the controller.
- Plan the split per channel. Each channel is usable as an analog input (0–30 V) or as a digital output (24 V). That is 16 channels in total, not 16 inputs plus 16 outputs.
- Two analog outputs, 0–10 V. For devices that take a 0–10 V control signal, controlled from the controller's scripts and logic.
- Scripts next to the I/O. The Lua scripting runs on the controller that owns the channels, so field signals can be used in Lua scripts alongside KNX objects.
- Trend and alert logs. Trend logs store sensor and consumption values at a set interval; the alert log records script alerts and KNX connection status.
- CAN FT for more I/O. When the channels of one unit are not enough, the CAN FT port connects CANx extension modules.
Where it fits in UAE projects
- Plant-room and riser panels where a few analog signals and 24 V outputs sit beside a KNX line.
- Retrofits that keep existing 0–30 V analog sensors or 0–10 V controlled devices and add KNX/TP and a web visualisation in the same controller.
No on-board I/O needed? The 4 DIN LM5p2-KC has the same CAN FT bus, and the LM5Lp2 is the compact entry model. Everything else is under LogicMachine.
Specifications
| Specification | Value |
|---|---|
| General | |
| Article number | LM5p2-RIO3 |
| Product range | LogicMachine5 KNX CANx |
| Manufacturer | Embedded Systems SIA, Riga, Latvia |
| Physical interfaces | |
| KNX/TP | 1 |
| CAN FT | 1 |
| RJ45 | 1 (10/100M Ethernet, passive PoE support) |
| RS-485 | 1 |
| RS-485 / RS-232 | 1 (switchable in software) |
| USB 2.0 | 1 |
| Analog inputs / Digital outputs | 16 (Inputs: 0-30 V / Outputs: 24 V) |
| Analog outputs | 2 (0-10 V) |
| Power | |
| Power supply | 24 V DC via terminals or passive PoE |
| Power consumption | 1.5 W (minimum, no external load) |
| Connections | |
| KNX bus / CAN FT bus | Bus connection terminal, 0.8 mm² |
| Power supply and I/O ports | Screw terminals, 0.8 mm² .. 1.5 mm² |
| Indicators | |
| LED 1 | Green – System load |
| LED 2 | Green – Normal operation / Red – Reset |
| Enclosure | |
| Mounting support | DIN rail |
| DIN module width | 6 |
| Dimensions WxHxD | 108 x 112 x 61 mm |
| IP degree of protection | IP20 |
| Net weight | 187 g |
| Standards compliance | |
| EMC | EN61000-6-1; EN61000-6-3 |
| Environment | |
| Operational temperature | 0 °C .. +45 °C |
| Storage temperature | -15 °C .. +55 °C |
| Relative humidity | 0% ... 93% (without condensation) |
| Warranty | 2 years |
Installation notes
- The datasheet gives the input range (0–30 V) and output level (24 V) but no output current or load rating. Check the connected devices' ratings before wiring loads.
- Ventilate or cool the panel in a UAE summer: the vendor's operating range ends at +45 °C.
Documents and safety
- LM5p2-RIO3 datasheet (PDF, 2026-11-05)
- LogicMachine comparison table (PDF)
- Safety information, installation and cybersecurity guidelines
Embedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.
Embedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.