{"product_id":"logicmachine5-reactor-io-v3-knx-canx-controller-lm5p2-rio3","title":"LogicMachine5 Reactor IO V3 KNX CANx Controller (LM5p2-RIO3)","description":"\u003cp\u003e\u003cstrong\u003eEach of the 16 channels works either as an analog input or as a digital output.\u003c\/strong\u003e The LogicMachine5 Reactor IO V3 (LM5p2-RIO3) adds two analog outputs, KNX\/TP and a CAN FT port, and the I\/O sits in a 6 DIN housing next to the controller.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan the split per channel.\u003c\/strong\u003e Each channel is usable as an analog input (0–30 V) or as a digital output (24 V). That is 16 channels in total, not 16 inputs plus 16 outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo analog outputs, 0–10 V.\u003c\/strong\u003e For devices that take a 0–10 V control signal, controlled from the controller's scripts and logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScripts next to the I\/O.\u003c\/strong\u003e The Lua scripting runs on the controller that owns the channels, so field signals can be used in Lua scripts alongside KNX objects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrend and alert logs.\u003c\/strong\u003e Trend logs store sensor and consumption values at a set interval; the alert log records script alerts and KNX connection status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN FT for more I\/O.\u003c\/strong\u003e When the channels of one unit are not enough, the CAN FT port connects \u003ca href=\"\/collections\/canx-extension-modules\" title=\"CANx extension modules for LogicMachine controllers on KNX Mall\"\u003eCANx extension modules\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhere it fits in UAE projects\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePlant-room and riser panels where a few analog signals and 24 V outputs sit beside a KNX line.\u003c\/li\u003e\n\u003cli\u003eRetrofits that keep existing 0–30 V analog sensors or 0–10 V controlled devices and add KNX\/TP and a web visualisation in the same controller.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNo on-board I\/O needed? The 4 DIN \u003ca href=\"\/products\/logicmachine5-knx-canx-controller-lm5p2-kc\" title=\"LogicMachine5 KNX CANx controller LM5p2-KC with CAN FT and two RS-485 ports\"\u003eLM5p2-KC\u003c\/a\u003e has the same CAN FT bus, and the \u003ca href=\"\/products\/logicmachine5-lite-power-knx-controller-lm5lp2\" title=\"LogicMachine5 Lite Power KNX controller LM5Lp2 in 3 DIN\"\u003eLM5Lp2\u003c\/a\u003e is the compact entry model. Everything else is under \u003ca href=\"\/collections\/logicmachine\" title=\"LogicMachine KNX controllers on KNX Mall\"\u003eLogicMachine\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eArticle number\u003c\/th\u003e\n\u003ctd\u003eLM5p2-RIO3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct range\u003c\/th\u003e\n\u003ctd\u003eLogicMachine5 KNX CANx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEmbedded Systems SIA, Riga, Latvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePhysical interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX\/TP\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCAN FT\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRJ45\u003c\/th\u003e\n\u003ctd\u003e1 (10\/100M Ethernet, passive PoE support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485 \/ RS-232\u003c\/th\u003e\n\u003ctd\u003e1 (switchable in software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB 2.0\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog inputs \/ Digital outputs\u003c\/th\u003e\n\u003ctd\u003e16 (Inputs: 0-30 V \/ Outputs: 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog outputs\u003c\/th\u003e\n\u003ctd\u003e2 (0-10 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC via terminals or passive PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e1.5 W (minimum, no external load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eConnections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX bus \/ CAN FT bus\u003c\/th\u003e\n\u003ctd\u003eBus connection terminal, 0.8 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply and I\/O ports\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.8 mm² .. 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eIndicators\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 1\u003c\/th\u003e\n\u003ctd\u003eGreen – System load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 2\u003c\/th\u003e\n\u003ctd\u003eGreen – Normal operation \/ Red – Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnclosure\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting support\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDIN module width\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions WxHxD\u003c\/th\u003e\n\u003ctd\u003e108 x 112 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e187 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eStandards compliance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61000-6-1; EN61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnvironment\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C .. +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-15 °C .. +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e0% ... 93% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe datasheet gives the input range (0–30 V) and output level (24 V) but no output current or load rating. Check the connected devices' ratings before wiring loads.\u003c\/li\u003e\n\u003cli\u003eVentilate or cool the panel in a UAE summer: the vendor's operating range ends at +45 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments and safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5p2-RIO3-20261105.pdf\" title=\"LogicMachine LM5p2-RIO3 datasheet, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLM5p2-RIO3 datasheet (PDF, 2026-11-05)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5-comparison-table-20260701.pdf\" title=\"LogicMachine comparison table of the LM5 models, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLogicMachine comparison table (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/safety-information\" title=\"Safety information and cybersecurity guidelines for LogicMachine, a page on logicmachine.net\" rel=\"noopener\"\u003eSafety information, installation and cybersecurity guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eEmbedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.\u003c\/p\u003e\u003cp\u003eEmbedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.\u003c\/p\u003e","brand":"LogicMachine","offers":[{"title":"Default Title","offer_id":67877449957661,"sku":"LM5p2-RIO3","price":7470.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/2223\/5933\/files\/LM5p2-RIO3.png?v=1793119950","url":"https:\/\/knxmall.ae\/products\/logicmachine5-reactor-io-v3-knx-canx-controller-lm5p2-rio3","provider":"KNX Mall","version":"1.0","type":"link"}