{"product_id":"logicmachine5-knx-canx-dali-controller-lm5p2-kcd","title":"LogicMachine5 KNX CANx DALI Controller (LM5p2-KCD)","description":"\u003cp\u003e\u003cstrong\u003eOne DALI line, a CAN FT port and KNX\/TP in a 4 DIN controller.\u003c\/strong\u003e The vendor's hardware page lists the DALI port of the LogicMachine5 KNX CANx DALI (LM5p2-KCD) as \"DALI x 1 (DALI2 supported)\", and the CAN FT port is there for later expansion.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN FT for expansion.\u003c\/strong\u003e The CAN FT port connects \u003ca href=\"\/collections\/canx-extension-modules\" title=\"CANx extension modules for LogicMachine controllers on KNX Mall\"\u003eCANx extension modules\u003c\/a\u003e, which sit on the CAN FT bus of a LogicMachine. The vendor's CANx range includes a DALI gateway.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScenes and schedules.\u003c\/strong\u003e Scenes control several data points at once or run timed sequences, and the scheduler starts events by time or at sunrise and sunset. Lua scripts hold the remaining logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisualisation for staff and owners.\u003c\/strong\u003e The built-in visualisation targets PCs, touch devices and big screens, locally and remotely.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhere it fits in UAE projects\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOffices and show suites with a DALI lighting zone next to KNX blinds and room controls, held by one controller.\u003c\/li\u003e\n\u003cli\u003eDALI panels in hospitality back-of-house, with plant read over Modbus RTU on the RS-485 port.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe \u003ca href=\"\/products\/logicmachine5-power-dw1-knx-controller-with-dali-and-1-wire-lm5p2-dw1\" title=\"LogicMachine5 Power DW1 KNX controller with two DALI lines and 1-Wire\"\u003eLM5p2-DW1\u003c\/a\u003e has two DALI lines, but the vendor lists them as \"DALI2 not supported\". Stand-alone DALI interfaces are under \u003ca href=\"\/collections\/knx-dali-gateways\" title=\"KNX DALI gateways in the KNX Mall catalogue\"\u003eKNX DALI gateways\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eArticle number\u003c\/th\u003e\n\u003ctd\u003eLM5p2-KCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct range\u003c\/th\u003e\n\u003ctd\u003eLogicMachine5 KNX CANx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEmbedded Systems SIA, Riga, Latvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePhysical interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX\/TP\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCAN FT\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRJ45\u003c\/th\u003e\n\u003ctd\u003e1 (10\/100M Ethernet, passive PoE support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485 \/ RS-232\u003c\/th\u003e\n\u003ctd\u003e1 (switchable in software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB 2.0\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDALI\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDALI2\u003c\/th\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC via terminals or passive PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e1.3 W (minimum, no external load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eConnections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX bus \/ CAN FT bus\u003c\/th\u003e\n\u003ctd\u003eBus connection terminal, 0.8 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply and I\/O ports\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.8 mm² .. 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eIndicators\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 1\u003c\/th\u003e\n\u003ctd\u003eGreen – System load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 2\u003c\/th\u003e\n\u003ctd\u003eGreen – Normal operation \/ Red – Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnclosure\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting support\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDIN module width\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions WxHxD\u003c\/th\u003e\n\u003ctd\u003e72 x 112 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e136 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eStandards compliance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61000-6-1; EN61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnvironment\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C .. +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-15 °C .. +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e0% ... 93% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eThe DALI-2 note is on the vendor's hardware page; the datasheet lists the DALI line without it. Neither gives the number of DALI devices per line or the DALI-2 device types the controller handles. Confirm both with the vendor before sizing the line.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eDocuments and safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5p2-KCD-20261105.pdf\" title=\"LogicMachine LM5p2-KCD datasheet, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLM5p2-KCD datasheet (PDF, 2026-11-05)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5-comparison-table-20260701.pdf\" title=\"LogicMachine comparison table of the LM5 models, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLogicMachine comparison table (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/safety-information\" title=\"Safety information and cybersecurity guidelines for LogicMachine, a page on logicmachine.net\" rel=\"noopener\"\u003eSafety information, installation and cybersecurity guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eEmbedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.\u003c\/p\u003e\u003cp\u003eEmbedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.\u003c\/p\u003e","brand":"LogicMachine","offers":[{"title":"Default Title","offer_id":67877449924893,"sku":"LM5p2-KCD","price":7025.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/2223\/5933\/files\/LM5p2-KCD.png?v=1793119950","url":"https:\/\/knxmall.ae\/products\/logicmachine5-knx-canx-dali-controller-lm5p2-kcd","provider":"KNX Mall","version":"1.0","type":"link"}