{"product_id":"logicmachine5-knx-canx-controller-lm5p2-kc","title":"LogicMachine5 KNX CANx Controller (LM5p2-KC)","description":"\u003cp\u003e\u003cstrong\u003eThe controller to start with when the project will grow through CANx modules.\u003c\/strong\u003e The LogicMachine5 KNX CANx (LM5p2-KC) adds a CAN FT port to KNX\/TP and has no DALI or on-board I\/O of its own: expansion goes through the CANx range.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN FT port for CANx.\u003c\/strong\u003e CANx devices sit on the CAN FT bus of a LogicMachine that has a CAN FT port. The LM5Lp2, LM5p2-DW1 and LM5p2-PMC have no CAN FT port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree serial ports, Modbus and BACnet.\u003c\/strong\u003e Two RS-485 ports and one RS-485 \/ RS-232 port that switches in software. BACnet\/IP server and Modbus RTU\/TCP master are built in; Modbus slave and BACnet client use the vendor's script libraries. Binary and numeric KNX objects with Export enabled can be read by a BACnet\/IP client. The vendor lists native support for KNX, Modbus, BACnet and MQTT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications and scripts.\u003c\/strong\u003e The vendor's application store offers pre-built applications, and Lua scripts cover site-specific logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote programming.\u003c\/strong\u003e Built-in WireGuard, OpenVPN and ZeroTier clients; the datasheet lists KNX device programming from a distance over VPN or ZeroTier.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhere it fits in UAE projects\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHotel and apartment-tower projects where room control stays on KNX and the specification asks for a BACnet\/IP link to the BMS.\u003c\/li\u003e\n\u003cli\u003ePlant rooms where RS-485 Modbus devices and an RS-232 device sit next to a KNX line.\u003c\/li\u003e\n\u003cli\u003ePhased fit-outs: install the controller with the first KNX floor and add \u003ca href=\"\/collections\/canx-extension-modules\" title=\"CANx extension modules for LogicMachine controllers on KNX Mall\"\u003eCANx extension modules\u003c\/a\u003e on the CAN FT bus as later phases arrive.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSame CAN FT bus, different jobs: the \u003ca href=\"\/products\/logicmachine5-knx-canx-dali-controller-lm5p2-kcd\" title=\"LogicMachine5 KNX CANx DALI controller LM5p2-KCD with CAN FT and one DALI line\"\u003eLM5p2-KCD\u003c\/a\u003e adds a DALI line and the \u003ca href=\"\/products\/logicmachine5-reactor-io-v3-knx-canx-controller-lm5p2-rio3\" title=\"LogicMachine5 Reactor IO V3 KNX CANx controller LM5p2-RIO3 with 16 analog-input-or-digital-output channels\"\u003eReactor IO V3 LM5p2-RIO3\u003c\/a\u003e adds 16 analog-input-or-digital-output channels. The whole range is under \u003ca href=\"\/collections\/logicmachine\" title=\"LogicMachine KNX controllers on KNX Mall\"\u003eLogicMachine\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eArticle number\u003c\/th\u003e\n\u003ctd\u003eLM5p2-KC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct range\u003c\/th\u003e\n\u003ctd\u003eLogicMachine5 KNX CANx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEmbedded Systems SIA, Riga, Latvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePhysical interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX\/TP\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCAN FT\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRJ45\u003c\/th\u003e\n\u003ctd\u003e1 (10\/100M Ethernet, passive PoE support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485 \/ RS-232\u003c\/th\u003e\n\u003ctd\u003e1 (switchable in software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB 2.0\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC via terminals or passive PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e1.1 W (minimum, no external load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eConnections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX bus \/ CAN FT bus\u003c\/th\u003e\n\u003ctd\u003eBus connection terminal, 0.8 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply and I\/O ports\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.8 mm² .. 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eIndicators\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 1\u003c\/th\u003e\n\u003ctd\u003eGreen – System load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 2\u003c\/th\u003e\n\u003ctd\u003eGreen – Normal operation \/ Red – Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnclosure\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting support\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDIN module width\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions WxHxD\u003c\/th\u003e\n\u003ctd\u003e72 x 112 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e137 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eStandards compliance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61000-6-1; EN61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnvironment\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C .. +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-15 °C .. +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e0% ... 93% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eCANx devices need a LogicMachine with a CAN FT port for commissioning and for connecting to other protocols, according to the vendor's CANx page.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eDocuments and safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5p2-KC-20261105.pdf\" title=\"LogicMachine LM5p2-KC datasheet, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLM5p2-KC datasheet (PDF, 2026-11-05)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5-comparison-table-20260701.pdf\" title=\"LogicMachine comparison table of the LM5 models, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLogicMachine comparison table (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/safety-information\" title=\"Safety information and cybersecurity guidelines for LogicMachine, a page on logicmachine.net\" rel=\"noopener\"\u003eSafety information, installation and cybersecurity guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eEmbedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.\u003c\/p\u003e\u003cp\u003eEmbedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.\u003c\/p\u003e","brand":"LogicMachine","offers":[{"title":"Default Title","offer_id":67877400838429,"sku":"LM5p2-KC","price":6710.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/2223\/5933\/files\/LM5p2-KC.png?v=1793119950","url":"https:\/\/knxmall.ae\/products\/logicmachine5-knx-canx-controller-lm5p2-kc","provider":"KNX Mall","version":"1.0","type":"link"}