{"title":"LogicMachine KNX","description":null,"products":[{"product_id":"logicmachine5-lite-power-knx-controller-lm5lp2","title":"LogicMachine5 Lite Power KNX Controller (LM5Lp2)","description":"\u003cp\u003e\u003cstrong\u003eA KNX controller for boards with little room.\u003c\/strong\u003e The LogicMachine5 Lite Power (LM5Lp2) is the narrowest LogicMachine5 KNX model (3 DIN; the others are 4 or 6 DIN). It has no DALI, 1-Wire, CAN FT or on-board analog\/digital I\/O, so the work it takes on is software: Lua scripts, schedules, scenes and protocol conversion.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree modules wide.\u003c\/strong\u003e One KNX\/TP line and one RJ45 port, powered with 24 V DC from the terminals or via passive PoE. It fits boards where the 4 and 6 DIN models do not.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial ports for Modbus.\u003c\/strong\u003e Use the RS-485 port for Modbus RTU devices, and switch the second port between RS-485 and RS-232 in software as the project needs. BACnet\/IP server and Modbus RTU\/TCP master are built in; Modbus slave and BACnet client use the vendor's script libraries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchedules that follow the sun.\u003c\/strong\u003e Events run at a set time, at sunrise or at sunset for the site's coordinates, with holiday rules. Facility staff can edit them in the user interface, without the admin tool.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisualisation, Apple Home and Google Home.\u003c\/strong\u003e Web visualisation for PCs, wall screens and mobile devices, locally and remotely. Apple Home runs through an app on the controller and a QR code; Google Home goes through the vendor's LM Cloud and needs an internet connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecured, and usable offline.\u003c\/strong\u003e KNX Data Secure, KNX\/IP secure routing and user-level permissions are listed in the datasheet. The controller is fully operational without internet access and sends no telemetry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhere it fits in UAE projects\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA villa or apartment with one KNX line: sunset-driven lighting scenes, a thermostat routine written in Lua and a tablet visualisation for the owner.\u003c\/li\u003e\n\u003cli\u003eA small office or retail unit where an RS-485 meter or an air-conditioning gateway has to reach the KNX line. The vendor publishes an integration example for CoolMasterNet VRF gateways over RS-232 or TCP (on\/off, mode, setpoint, fan speed).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eIf the project later needs DALI or a CAN FT bus, step up to the \u003ca href=\"\/products\/logicmachine5-power-dw1-knx-controller-with-dali-and-1-wire-lm5p2-dw1\" title=\"LogicMachine5 Power DW1 KNX controller with two DALI lines and 1-Wire\"\u003eLM5p2-DW1 with two DALI lines\u003c\/a\u003e or the \u003ca href=\"\/products\/logicmachine5-knx-canx-controller-lm5p2-kc\" title=\"LogicMachine5 KNX CANx controller LM5p2-KC with CAN FT\"\u003eLM5p2-KC with CAN FT\u003c\/a\u003e. The rest of the range is under \u003ca href=\"\/collections\/logicmachine\" title=\"LogicMachine KNX controllers on KNX Mall\"\u003eLogicMachine\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eArticle number\u003c\/th\u003e\n\u003ctd\u003eLM5Lp2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct range\u003c\/th\u003e\n\u003ctd\u003eLogicMachine5 KNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEmbedded Systems SIA, Riga, Latvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePhysical interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX\/TP\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRJ45\u003c\/th\u003e\n\u003ctd\u003e1 (10\/100M Ethernet, passive PoE support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485 \/ RS-232\u003c\/th\u003e\n\u003ctd\u003e1 (switchable in software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB 2.0\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC via terminals or passive PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e1 W (minimum, no external load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eConnections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX bus\u003c\/th\u003e\n\u003ctd\u003eBus connection terminal, 0.8 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply and I\/O ports\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.8 mm² .. 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eIndicators\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 1\u003c\/th\u003e\n\u003ctd\u003eGreen – System load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 2\u003c\/th\u003e\n\u003ctd\u003eGreen – Normal operation \/ Red – Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnclosure\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting support\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDIN module width\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions WxHxD\u003c\/th\u003e\n\u003ctd\u003e54 x 112 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e108 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eStandards compliance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61000-6-1; EN61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnvironment\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C .. +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-15 °C .. +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e0% ... 93% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVentilate or cool the panel in a UAE summer: the vendor's operating range ends at +45 °C.\u003c\/li\u003e\n\u003cli\u003eThe vendor does not publish CPU, RAM or object limits for this model. Confirm them with the vendor before specifying a large project or a heavy visualisation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments and safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5Lp2-20261105.pdf\" title=\"LogicMachine LM5Lp2 datasheet, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLM5Lp2 datasheet (PDF, 2026-11-05)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5-comparison-table-20260701.pdf\" title=\"LogicMachine comparison table of the LM5 models, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLogicMachine comparison table (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/safety-information\" title=\"Safety information and cybersecurity guidelines for LogicMachine, a page on logicmachine.net\" rel=\"noopener\"\u003eSafety information, installation and cybersecurity guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eEmbedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.\u003c\/p\u003e\u003cp\u003eEmbedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.\u003c\/p\u003e","brand":"LogicMachine","offers":[{"title":"Default Title","offer_id":67877399134493,"sku":"LM5Lp2","price":6015.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/2223\/5933\/files\/LM5Lp2.png?v=1793119949"},{"product_id":"logicmachine5-power-dw1-knx-controller-with-dali-and-1-wire-lm5p2-dw1","title":"LogicMachine5 Power DW1 KNX Controller with DALI and 1-Wire (LM5p2-DW1)","description":"\u003cp\u003e\u003cstrong\u003eTwo DALI lines and two 1-Wire ports on one KNX controller.\u003c\/strong\u003e The LogicMachine5 Power DW1 (LM5p2-DW1) puts KNX\/TP, two DALI lines and two 1-Wire ports in a 4 DIN housing. The vendor's hardware page lists its DALI ports as \"DALI2 not supported\", so the model suits installations that stay on DALI (version 1).\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo DALI lines.\u003c\/strong\u003e Two DALI ports in 4 DIN modules, listed by the vendor as \"DALI2 not supported\". Where the design requires a DALI line that the vendor's hardware page lists as \"DALI2 supported\", use the LM5p2-KCD (link below).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo 1-Wire ports.\u003c\/strong\u003e Among the LogicMachine5 KNX controllers, only the DW1 has 1-Wire ports. Check the vendor's documentation for the supported 1-Wire devices before specifying sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEverything else on board.\u003c\/strong\u003e Alongside the two buses: Ethernet with passive PoE, one RS-485 port and one RS-485 \/ RS-232 port that switches in software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLua for site-specific logic.\u003c\/strong\u003e The vendor lists Lua scripting for process automation, complex logic and data manipulation, and an application store with pre-built applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhere it fits in UAE projects\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVillas and apartments where DALI lighting and the KNX switches are handled in the same Lua logic.\u003c\/li\u003e\n\u003cli\u003eHotel corridors, lobbies and back-of-house areas lit over DALI lines and kept in one panel with the KNX room controls.\u003c\/li\u003e\n\u003cli\u003eRetrofit boards that already carry a DALI line (this model is listed as \"DALI2 not supported\" on the vendor's hardware page) and need KNX logic and a web visualisation without a second controller type.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe \u003ca href=\"\/products\/logicmachine5-knx-canx-dali-controller-lm5p2-kcd\" title=\"LogicMachine5 KNX CANx DALI controller LM5p2-KCD, one DALI line listed as DALI2 supported\"\u003eLM5p2-KCD\u003c\/a\u003e is the model whose DALI line the vendor lists as \"DALI2 supported\". Stand-alone interfaces are under \u003ca href=\"\/collections\/knx-dali-gateways\" title=\"KNX DALI gateways in the KNX Mall catalogue\"\u003eKNX DALI gateways\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eArticle number\u003c\/th\u003e\n\u003ctd\u003eLM5p2-DW1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct range\u003c\/th\u003e\n\u003ctd\u003eLogicMachine5 KNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEmbedded Systems SIA, Riga, Latvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePhysical interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX\/TP\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRJ45\u003c\/th\u003e\n\u003ctd\u003e1 (10\/100M Ethernet, passive PoE support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485 \/ RS-232\u003c\/th\u003e\n\u003ctd\u003e1 (switchable in software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB 2.0\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDALI\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDALI2\u003c\/th\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1-Wire\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC via terminals or passive PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e1 W (minimum, no external load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eConnections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX bus\u003c\/th\u003e\n\u003ctd\u003eBus connection terminal, 0.8 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply and I\/O ports\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.8 mm² .. 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eIndicators\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 1\u003c\/th\u003e\n\u003ctd\u003eGreen – System load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 2\u003c\/th\u003e\n\u003ctd\u003eGreen – Normal operation \/ Red – Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnclosure\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting support\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDIN module width\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions WxHxD\u003c\/th\u003e\n\u003ctd\u003e72 x 112 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e137 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eStandards compliance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61000-6-1; EN61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnvironment\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C .. +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-15 °C .. +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e0% ... 93% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe datasheet does not state the number of DALI devices per line. Ask the vendor before sizing a line.\u003c\/li\u003e\n\u003cli\u003eThis model has no CAN FT port, so CANx modules cannot be attached to it.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments and safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5p2-DW1-20261105.pdf\" title=\"LogicMachine LM5p2-DW1 datasheet, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLM5p2-DW1 datasheet (PDF, 2026-11-05)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5-comparison-table-20260701.pdf\" title=\"LogicMachine comparison table of the LM5 models, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLogicMachine comparison table (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/safety-information\" title=\"Safety information and cybersecurity guidelines for LogicMachine, a page on logicmachine.net\" rel=\"noopener\"\u003eSafety information, installation and cybersecurity guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eEmbedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.\u003c\/p\u003e\u003cp\u003eEmbedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.\u003c\/p\u003e","brand":"LogicMachine","offers":[{"title":"Default Title","offer_id":67877399494941,"sku":"LM5p2-DW1","price":7025.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/2223\/5933\/files\/LM5p2-DW1.png?v=1793119949"},{"product_id":"logicmachine5-choke-knx-controller-lm5p2-pmc","title":"LogicMachine5 Choke KNX Controller (LM5p2-PMC)","description":"\u003cp\u003e\u003cstrong\u003eA KNX controller with the KNX choke built in.\u003c\/strong\u003e The LogicMachine5 Choke (LM5p2-PMC) combines the controller functions and the choke in a single 4 DIN housing, with Ethernet, RS-485 and USB on board.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in KNX choke.\u003c\/strong\u003e The vendor lists it in its comparison table, and the datasheet gives a KNX power terminal for 24–29 V DC at the top left of the housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrend logs for meters and sensors.\u003c\/strong\u003e Values are recorded at a set interval and charted. The vendor's log types are counter, counter with negative delta and absolute value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlerts and messages from scripts.\u003c\/strong\u003e The alert log lists script alerts and KNX connection status. Email, push through the LM Home app (via the vendor's LM Cloud) and Telegram messages are set up in scripts; these need an internet connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote access built in.\u003c\/strong\u003e OpenVPN, WireGuard and ZeroTier clients are on the controller, and the datasheet lists KNX device programming from anywhere over VPN or ZeroTier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecured, and usable offline.\u003c\/strong\u003e KNX Data Secure, KNX\/IP secure routing and user-level permissions are listed in the datasheet. The controller is fully operational without internet access (cloud features are optional) and sends no telemetry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhere it fits in UAE projects\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCompact riser or apartment boards where one 4 DIN device carries both the controller and the KNX choke.\u003c\/li\u003e\n\u003cli\u003eEnergy-monitoring panels that keep trend logs of meter values on site.\u003c\/li\u003e\n\u003cli\u003ePanels in managed buildings that the integrator programs from the office over VPN.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor the same controller without the choke, look at the \u003ca href=\"\/products\/logicmachine5-lite-power-knx-controller-lm5lp2\" title=\"LogicMachine5 Lite Power KNX controller LM5Lp2 in 3 DIN\"\u003eLM5Lp2 in 3 DIN\u003c\/a\u003e or the \u003ca href=\"\/products\/logicmachine5-knx-canx-controller-lm5p2-kc\" title=\"LogicMachine5 KNX CANx controller LM5p2-KC with CAN FT\"\u003eLM5p2-KC with a CAN FT port\u003c\/a\u003e; the whole range is under \u003ca href=\"\/collections\/logicmachine\" title=\"LogicMachine KNX controllers on KNX Mall\"\u003eLogicMachine\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eArticle number\u003c\/th\u003e\n\u003ctd\u003eLM5p2-PMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct range\u003c\/th\u003e\n\u003ctd\u003eLogicMachine5 KNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEmbedded Systems SIA, Riga, Latvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePhysical interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX\/TP\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRJ45\u003c\/th\u003e\n\u003ctd\u003e1 (10\/100M Ethernet, passive PoE support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485 \/ RS-232\u003c\/th\u003e\n\u003ctd\u003e1 (switchable in software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB 2.0\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAdditional features (vendor comparison table)\u003c\/th\u003e\n\u003ctd\u003eBuilt-in KNX choke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC via terminals or passive PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e1 W (minimum, no external load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX power\u003c\/th\u003e\n\u003ctd\u003e24 .. 29 V DC (top left power terminal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX bus current\u003c\/th\u003e\n\u003ctd\u003eNot stated by the vendor (requires verification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eConnections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX bus\u003c\/th\u003e\n\u003ctd\u003eBus connection terminal, 0.8 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply and I\/O ports\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.8 mm² .. 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eIndicators\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 1\u003c\/th\u003e\n\u003ctd\u003eGreen – System load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 2\u003c\/th\u003e\n\u003ctd\u003eGreen – Normal operation \/ Red – Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnclosure\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting support\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDIN module width\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions WxHxD\u003c\/th\u003e\n\u003ctd\u003e72 x 112 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e153 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eStandards compliance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61000-6-1; EN61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnvironment\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C .. +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-15 °C .. +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e0% ... 93% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe vendor gives no KNX bus current and does not say whether a separate KNX power supply or choke is still needed with this model. Confirm the KNX power concept and the line load with the vendor before ordering.\u003c\/li\u003e\n\u003cli\u003eVentilate or cool the panel in a UAE summer: the vendor's operating range ends at +45 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments and safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5p2-PMC-20261105.pdf\" title=\"LogicMachine LM5p2-PMC datasheet, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLM5p2-PMC datasheet (PDF, 2026-11-05)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5-comparison-table-20260701.pdf\" title=\"LogicMachine comparison table of the LM5 models, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLogicMachine comparison table (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/safety-information\" title=\"Safety information and cybersecurity guidelines for LogicMachine, a page on logicmachine.net\" rel=\"noopener\"\u003eSafety information, installation and cybersecurity guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eEmbedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.\u003c\/p\u003e\u003cp\u003eEmbedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.\u003c\/p\u003e","brand":"LogicMachine","offers":[{"title":"Default Title","offer_id":67877400346909,"sku":"LM5p2-PMC","price":6455.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/2223\/5933\/files\/LM5p2-PMC.png?v=1793119949"},{"product_id":"logicmachine5-knx-canx-controller-lm5p2-kc","title":"LogicMachine5 KNX CANx Controller (LM5p2-KC)","description":"\u003cp\u003e\u003cstrong\u003eThe controller to start with when the project will grow through CANx modules.\u003c\/strong\u003e The LogicMachine5 KNX CANx (LM5p2-KC) adds a CAN FT port to KNX\/TP and has no DALI or on-board I\/O of its own: expansion goes through the CANx range.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN FT port for CANx.\u003c\/strong\u003e CANx devices sit on the CAN FT bus of a LogicMachine that has a CAN FT port. The LM5Lp2, LM5p2-DW1 and LM5p2-PMC have no CAN FT port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree serial ports, Modbus and BACnet.\u003c\/strong\u003e Two RS-485 ports and one RS-485 \/ RS-232 port that switches in software. BACnet\/IP server and Modbus RTU\/TCP master are built in; Modbus slave and BACnet client use the vendor's script libraries. Binary and numeric KNX objects with Export enabled can be read by a BACnet\/IP client. The vendor lists native support for KNX, Modbus, BACnet and MQTT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications and scripts.\u003c\/strong\u003e The vendor's application store offers pre-built applications, and Lua scripts cover site-specific logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote programming.\u003c\/strong\u003e Built-in WireGuard, OpenVPN and ZeroTier clients; the datasheet lists KNX device programming from a distance over VPN or ZeroTier.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhere it fits in UAE projects\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHotel and apartment-tower projects where room control stays on KNX and the specification asks for a BACnet\/IP link to the BMS.\u003c\/li\u003e\n\u003cli\u003ePlant rooms where RS-485 Modbus devices and an RS-232 device sit next to a KNX line.\u003c\/li\u003e\n\u003cli\u003ePhased fit-outs: install the controller with the first KNX floor and add \u003ca href=\"\/collections\/canx-extension-modules\" title=\"CANx extension modules for LogicMachine controllers on KNX Mall\"\u003eCANx extension modules\u003c\/a\u003e on the CAN FT bus as later phases arrive.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSame CAN FT bus, different jobs: the \u003ca href=\"\/products\/logicmachine5-knx-canx-dali-controller-lm5p2-kcd\" title=\"LogicMachine5 KNX CANx DALI controller LM5p2-KCD with CAN FT and one DALI line\"\u003eLM5p2-KCD\u003c\/a\u003e adds a DALI line and the \u003ca href=\"\/products\/logicmachine5-reactor-io-v3-knx-canx-controller-lm5p2-rio3\" title=\"LogicMachine5 Reactor IO V3 KNX CANx controller LM5p2-RIO3 with 16 analog-input-or-digital-output channels\"\u003eReactor IO V3 LM5p2-RIO3\u003c\/a\u003e adds 16 analog-input-or-digital-output channels. The whole range is under \u003ca href=\"\/collections\/logicmachine\" title=\"LogicMachine KNX controllers on KNX Mall\"\u003eLogicMachine\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eArticle number\u003c\/th\u003e\n\u003ctd\u003eLM5p2-KC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct range\u003c\/th\u003e\n\u003ctd\u003eLogicMachine5 KNX CANx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEmbedded Systems SIA, Riga, Latvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePhysical interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX\/TP\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCAN FT\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRJ45\u003c\/th\u003e\n\u003ctd\u003e1 (10\/100M Ethernet, passive PoE support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485 \/ RS-232\u003c\/th\u003e\n\u003ctd\u003e1 (switchable in software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB 2.0\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC via terminals or passive PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e1.1 W (minimum, no external load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eConnections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX bus \/ CAN FT bus\u003c\/th\u003e\n\u003ctd\u003eBus connection terminal, 0.8 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply and I\/O ports\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.8 mm² .. 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eIndicators\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 1\u003c\/th\u003e\n\u003ctd\u003eGreen – System load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 2\u003c\/th\u003e\n\u003ctd\u003eGreen – Normal operation \/ Red – Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnclosure\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting support\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDIN module width\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions WxHxD\u003c\/th\u003e\n\u003ctd\u003e72 x 112 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e137 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eStandards compliance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61000-6-1; EN61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnvironment\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C .. +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-15 °C .. +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e0% ... 93% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eCANx devices need a LogicMachine with a CAN FT port for commissioning and for connecting to other protocols, according to the vendor's CANx page.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eDocuments and safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5p2-KC-20261105.pdf\" title=\"LogicMachine LM5p2-KC datasheet, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLM5p2-KC datasheet (PDF, 2026-11-05)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5-comparison-table-20260701.pdf\" title=\"LogicMachine comparison table of the LM5 models, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLogicMachine comparison table (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/safety-information\" title=\"Safety information and cybersecurity guidelines for LogicMachine, a page on logicmachine.net\" rel=\"noopener\"\u003eSafety information, installation and cybersecurity guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eEmbedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.\u003c\/p\u003e\u003cp\u003eEmbedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.\u003c\/p\u003e","brand":"LogicMachine","offers":[{"title":"Default Title","offer_id":67877400838429,"sku":"LM5p2-KC","price":6710.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/2223\/5933\/files\/LM5p2-KC.png?v=1793119950"},{"product_id":"logicmachine5-knx-canx-dali-controller-lm5p2-kcd","title":"LogicMachine5 KNX CANx DALI Controller (LM5p2-KCD)","description":"\u003cp\u003e\u003cstrong\u003eOne DALI line, a CAN FT port and KNX\/TP in a 4 DIN controller.\u003c\/strong\u003e The vendor's hardware page lists the DALI port of the LogicMachine5 KNX CANx DALI (LM5p2-KCD) as \"DALI x 1 (DALI2 supported)\", and the CAN FT port is there for later expansion.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN FT for expansion.\u003c\/strong\u003e The CAN FT port connects \u003ca href=\"\/collections\/canx-extension-modules\" title=\"CANx extension modules for LogicMachine controllers on KNX Mall\"\u003eCANx extension modules\u003c\/a\u003e, which sit on the CAN FT bus of a LogicMachine. The vendor's CANx range includes a DALI gateway.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScenes and schedules.\u003c\/strong\u003e Scenes control several data points at once or run timed sequences, and the scheduler starts events by time or at sunrise and sunset. Lua scripts hold the remaining logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisualisation for staff and owners.\u003c\/strong\u003e The built-in visualisation targets PCs, touch devices and big screens, locally and remotely.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhere it fits in UAE projects\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOffices and show suites with a DALI lighting zone next to KNX blinds and room controls, held by one controller.\u003c\/li\u003e\n\u003cli\u003eDALI panels in hospitality back-of-house, with plant read over Modbus RTU on the RS-485 port.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe \u003ca href=\"\/products\/logicmachine5-power-dw1-knx-controller-with-dali-and-1-wire-lm5p2-dw1\" title=\"LogicMachine5 Power DW1 KNX controller with two DALI lines and 1-Wire\"\u003eLM5p2-DW1\u003c\/a\u003e has two DALI lines, but the vendor lists them as \"DALI2 not supported\". Stand-alone DALI interfaces are under \u003ca href=\"\/collections\/knx-dali-gateways\" title=\"KNX DALI gateways in the KNX Mall catalogue\"\u003eKNX DALI gateways\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eArticle number\u003c\/th\u003e\n\u003ctd\u003eLM5p2-KCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct range\u003c\/th\u003e\n\u003ctd\u003eLogicMachine5 KNX CANx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEmbedded Systems SIA, Riga, Latvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePhysical interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX\/TP\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCAN FT\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRJ45\u003c\/th\u003e\n\u003ctd\u003e1 (10\/100M Ethernet, passive PoE support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485 \/ RS-232\u003c\/th\u003e\n\u003ctd\u003e1 (switchable in software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB 2.0\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDALI\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDALI2\u003c\/th\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC via terminals or passive PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e1.3 W (minimum, no external load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eConnections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX bus \/ CAN FT bus\u003c\/th\u003e\n\u003ctd\u003eBus connection terminal, 0.8 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply and I\/O ports\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.8 mm² .. 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eIndicators\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 1\u003c\/th\u003e\n\u003ctd\u003eGreen – System load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 2\u003c\/th\u003e\n\u003ctd\u003eGreen – Normal operation \/ Red – Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnclosure\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting support\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDIN module width\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions WxHxD\u003c\/th\u003e\n\u003ctd\u003e72 x 112 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e136 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eStandards compliance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61000-6-1; EN61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnvironment\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C .. +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-15 °C .. +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e0% ... 93% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eThe DALI-2 note is on the vendor's hardware page; the datasheet lists the DALI line without it. Neither gives the number of DALI devices per line or the DALI-2 device types the controller handles. Confirm both with the vendor before sizing the line.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eDocuments and safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5p2-KCD-20261105.pdf\" title=\"LogicMachine LM5p2-KCD datasheet, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLM5p2-KCD datasheet (PDF, 2026-11-05)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5-comparison-table-20260701.pdf\" title=\"LogicMachine comparison table of the LM5 models, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLogicMachine comparison table (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/safety-information\" title=\"Safety information and cybersecurity guidelines for LogicMachine, a page on logicmachine.net\" rel=\"noopener\"\u003eSafety information, installation and cybersecurity guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eEmbedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.\u003c\/p\u003e\u003cp\u003eEmbedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.\u003c\/p\u003e","brand":"LogicMachine","offers":[{"title":"Default Title","offer_id":67877449924893,"sku":"LM5p2-KCD","price":7025.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/2223\/5933\/files\/LM5p2-KCD.png?v=1793119950"},{"product_id":"logicmachine5-reactor-io-v3-knx-canx-controller-lm5p2-rio3","title":"LogicMachine5 Reactor IO V3 KNX CANx Controller (LM5p2-RIO3)","description":"\u003cp\u003e\u003cstrong\u003eEach of the 16 channels works either as an analog input or as a digital output.\u003c\/strong\u003e The LogicMachine5 Reactor IO V3 (LM5p2-RIO3) adds two analog outputs, KNX\/TP and a CAN FT port, and the I\/O sits in a 6 DIN housing next to the controller.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan the split per channel.\u003c\/strong\u003e Each channel is usable as an analog input (0–30 V) or as a digital output (24 V). That is 16 channels in total, not 16 inputs plus 16 outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo analog outputs, 0–10 V.\u003c\/strong\u003e For devices that take a 0–10 V control signal, controlled from the controller's scripts and logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScripts next to the I\/O.\u003c\/strong\u003e The Lua scripting runs on the controller that owns the channels, so field signals can be used in Lua scripts alongside KNX objects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrend and alert logs.\u003c\/strong\u003e Trend logs store sensor and consumption values at a set interval; the alert log records script alerts and KNX connection status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN FT for more I\/O.\u003c\/strong\u003e When the channels of one unit are not enough, the CAN FT port connects \u003ca href=\"\/collections\/canx-extension-modules\" title=\"CANx extension modules for LogicMachine controllers on KNX Mall\"\u003eCANx extension modules\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhere it fits in UAE projects\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePlant-room and riser panels where a few analog signals and 24 V outputs sit beside a KNX line.\u003c\/li\u003e\n\u003cli\u003eRetrofits that keep existing 0–30 V analog sensors or 0–10 V controlled devices and add KNX\/TP and a web visualisation in the same controller.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNo on-board I\/O needed? The 4 DIN \u003ca href=\"\/products\/logicmachine5-knx-canx-controller-lm5p2-kc\" title=\"LogicMachine5 KNX CANx controller LM5p2-KC with CAN FT and two RS-485 ports\"\u003eLM5p2-KC\u003c\/a\u003e has the same CAN FT bus, and the \u003ca href=\"\/products\/logicmachine5-lite-power-knx-controller-lm5lp2\" title=\"LogicMachine5 Lite Power KNX controller LM5Lp2 in 3 DIN\"\u003eLM5Lp2\u003c\/a\u003e is the compact entry model. Everything else is under \u003ca href=\"\/collections\/logicmachine\" title=\"LogicMachine KNX controllers on KNX Mall\"\u003eLogicMachine\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eArticle number\u003c\/th\u003e\n\u003ctd\u003eLM5p2-RIO3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct range\u003c\/th\u003e\n\u003ctd\u003eLogicMachine5 KNX CANx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEmbedded Systems SIA, Riga, Latvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePhysical interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX\/TP\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCAN FT\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRJ45\u003c\/th\u003e\n\u003ctd\u003e1 (10\/100M Ethernet, passive PoE support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-485 \/ RS-232\u003c\/th\u003e\n\u003ctd\u003e1 (switchable in software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB 2.0\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog inputs \/ Digital outputs\u003c\/th\u003e\n\u003ctd\u003e16 (Inputs: 0-30 V \/ Outputs: 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog outputs\u003c\/th\u003e\n\u003ctd\u003e2 (0-10 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC via terminals or passive PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e1.5 W (minimum, no external load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eConnections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKNX bus \/ CAN FT bus\u003c\/th\u003e\n\u003ctd\u003eBus connection terminal, 0.8 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply and I\/O ports\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.8 mm² .. 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eIndicators\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 1\u003c\/th\u003e\n\u003ctd\u003eGreen – System load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLED 2\u003c\/th\u003e\n\u003ctd\u003eGreen – Normal operation \/ Red – Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnclosure\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting support\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDIN module width\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions WxHxD\u003c\/th\u003e\n\u003ctd\u003e108 x 112 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e187 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eStandards compliance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61000-6-1; EN61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnvironment\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C .. +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-15 °C .. +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e0% ... 93% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe datasheet gives the input range (0–30 V) and output level (24 V) but no output current or load rating. Check the connected devices' ratings before wiring loads.\u003c\/li\u003e\n\u003cli\u003eVentilate or cool the panel in a UAE summer: the vendor's operating range ends at +45 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments and safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5p2-RIO3-20261105.pdf\" title=\"LogicMachine LM5p2-RIO3 datasheet, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLM5p2-RIO3 datasheet (PDF, 2026-11-05)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/LM5-comparison-table-20260701.pdf\" title=\"LogicMachine comparison table of the LM5 models, a PDF on logicmachine.net\" rel=\"noopener\"\u003eLogicMachine comparison table (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/safety-information\" title=\"Safety information and cybersecurity guidelines for LogicMachine, a page on logicmachine.net\" rel=\"noopener\"\u003eSafety information, installation and cybersecurity guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eEmbedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.\u003c\/p\u003e\u003cp\u003eEmbedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.\u003c\/p\u003e","brand":"LogicMachine","offers":[{"title":"Default Title","offer_id":67877449957661,"sku":"LM5p2-RIO3","price":7470.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/2223\/5933\/files\/LM5p2-RIO3.png?v=1793119950"},{"product_id":"logicmachine-canx-dali-gateway-can-dali-m3","title":"LogicMachine CANx DALI Gateway (CAN-DALI-M3)","description":"\u003cp\u003eConnects DALI lighting systems with CANx-based building automation networks. The vendor lists it as \"Supports DALI-1 and DALI-2 with multi-master capability\". Offers individual, group and broadcast control. Supports DALI scenes, tunable white and RGB\/RGBW.\u003c\/p\u003e\u003cp\u003eCANx device: its bus interface is CAN FT, not KNX\/TP. Vendor note: «LogicMachine5 is required for operation».\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eArticle number\u003c\/th\u003e\n\u003ctd\u003eCAN-DALI-M3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct range\u003c\/th\u003e\n\u003ctd\u003eLogicMachine CANx devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEmbedded Systems SIA, Riga, Latvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePhysical interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDALI\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCAN FT\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProgramming \/ Reset button\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB 2.0\u003c\/th\u003e\n\u003ctd\u003e1 (only for device firmware upgrade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain power supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDALI bus power supply\u003c\/th\u003e\n\u003ctd\u003e15 V .. 18 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e0.72 W (stand-by), 1.4 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eConnections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCANx bus\u003c\/th\u003e\n\u003ctd\u003eBus connection terminal, 0.8 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply and DALI\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.8 mm² .. 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eLED indicators\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGreen\u003c\/th\u003e\n\u003ctd\u003eBus activity \/ programming mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRed\u003c\/th\u003e\n\u003ctd\u003eBus or hardware fault \/ reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnclosure\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting support\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDIN module width\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions WxHxD\u003c\/th\u003e\n\u003ctd\u003e54 x 114 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e86 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eStandards compliance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61000-6-1; EN61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnvironment\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C .. +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-15 °C .. +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e0% ... 93% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eDocuments and safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/canx\/CAN-DALI-M3-20260701.pdf\" title=\"LogicMachine CAN-DALI-M3 datasheet, a PDF on logicmachine.net\" rel=\"noopener\"\u003eCAN-DALI-M3 datasheet (PDF, 2026-07-01)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/canx-hardware\" title=\"LogicMachine CANx hardware range, a page on logicmachine.net\" rel=\"noopener\"\u003eLogicMachine CANx hardware\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/safety-information\" title=\"Safety information and cybersecurity guidelines for LogicMachine, a page on logicmachine.net\" rel=\"noopener\"\u003eSafety information, installation and cybersecurity guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eEmbedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.\u003c\/p\u003e\u003cp\u003eEmbedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.\u003c\/p\u003e","brand":"LogicMachine","offers":[{"title":"Default Title","offer_id":67877450023197,"sku":"CAN-DALI-M3","price":950.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/2223\/5933\/files\/CAN-DALI-M3.png?v=1793119950"},{"product_id":"logicmachine-canx-16-x-analog-inputs-digital-outputs-can-uio16","title":"LogicMachine CANx 16 x Analog Inputs \/ Digital Outputs (CAN-UIO16)","description":"\u003cp\u003eCAN-UIO16 is a DIN-rail mounted universal I\/O module featuring 16 configurable analog inputs or digital outputs, designed for signal control in building automation systems.\u003c\/p\u003e\u003cp\u003eCANx device: its bus interface is CAN FT, not KNX\/TP. Vendor note: «LogicMachine CANx is required for commissioning and inter-connectivity with other protocols».\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eArticle number\u003c\/th\u003e\n\u003ctd\u003eCAN-UIO16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct range\u003c\/th\u003e\n\u003ctd\u003eLogicMachine CANx devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEmbedded Systems SIA, Riga, Latvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePhysical interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCAN FT\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProgramming \/ Reset button\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB 2.0\u003c\/th\u003e\n\u003ctd\u003e1 (only for device firmware upgrade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog input \/ Digital output\u003c\/th\u003e\n\u003ctd\u003e16 (Inputs: 0-30 V \/ Outputs: 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDigital output current\u003c\/th\u003e\n\u003ctd\u003e350 mA (max 2 A per whole device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e0.40 W (stand-by), 0.90 W (max w\/o load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eConnections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCANx bus\u003c\/th\u003e\n\u003ctd\u003eBus connection terminal, 0.8 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply and I\/O\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.8 mm² .. 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eLED indicators\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGreen\u003c\/th\u003e\n\u003ctd\u003eBus activity \/ programming mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRed\u003c\/th\u003e\n\u003ctd\u003eBus or hardware fault \/ reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnclosure\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting support\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDIN module width\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions WxHxD\u003c\/th\u003e\n\u003ctd\u003e54 x 110 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e87 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eStandards compliance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN61000-6-1; EN61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eEnvironment\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C .. +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-15 °C .. +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e0% ... 93% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eDocuments and safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/datasheets\/canx\/CAN-UIO16-20260701.pdf\" title=\"LogicMachine CAN-UIO16 datasheet, a PDF on logicmachine.net\" rel=\"noopener\"\u003eCAN-UIO16 datasheet (PDF, 2026-07-01)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/canx-hardware\" title=\"LogicMachine CANx hardware range, a page on logicmachine.net\" rel=\"noopener\"\u003eLogicMachine CANx hardware\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/logicmachine.net\/safety-information\" title=\"Safety information and cybersecurity guidelines for LogicMachine, a page on logicmachine.net\" rel=\"noopener\"\u003eSafety information, installation and cybersecurity guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eEmbedded Systems SIA equipment must be installed, operated, serviced and maintained only by qualified personnel.\u003c\/p\u003e\u003cp\u003eEmbedded Systems SIA equipment is not rated, tested or certified for use in life-safety, mission-critical or fail-safe operational environments.\u003c\/p\u003e","brand":"LogicMachine","offers":[{"title":"Default Title","offer_id":67877450055965,"sku":"CAN-UIO16","price":890.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/2223\/5933\/files\/CAN-UIO16.png?v=1793119950"}],"url":"https:\/\/knxmall.ae\/collections\/logicmachine.oembed","provider":"KNX Mall","version":"1.0","type":"link"}